解决炼钢闭路循环水水温超设计值的对策
引用本文:俞琴,李英,伊江明.解决炼钢闭路循环水水温超设计值的对策[J].工业安全与环保,2007,33(2):35-37.
作者姓名:俞琴  李英  伊江明
作者单位:1. 武钢能源动力公司供水厂,武汉,430083
2. 武汉钢电股份有限公司,武汉,430083
摘    要:针对武钢一炼钢闭路循环水水温超设计值,影响正常生产的现状,从工艺、水质控制的调查、分析入手,提出了有效的对策措施,并加以实施,取得了较好效果,可为同类系统的水质控制提供参考.

关 键 词:闭路净环水  水温  设计值  对策
修稿时间:2006-04-13

Countermeasures for Solving the Problem that Closed-circuit Cycled Water Temperature exceeds the Planned Value
YU Qin,LI Ying,YI Jiang-ming.Countermeasures for Solving the Problem that Closed-circuit Cycled Water Temperature exceeds the Planned Value[J].Industrial Safety and Dust Control,2007,33(2):35-37.
Authors:YU Qin  LI Ying  YI Jiang-ming
Institution:Water Supply Plant, Energy Sources and Power Supply Co., WISCO Wuhan 430080
Abstract:Beginning from the investigation and analysis on the techniques and water quality control,some effective countermeasures are put forward and implemented,and good benefits have been obtained,which can provide references for water quality control of the same kind of system,according to the present status that closed-circuit cycled water temperature exceeds the planned value in No.1 Steelworks of WISCO,which affects normal production.
Keywords:closed-circuit cycled water water temperature planned value countermeasure