Droplet charging for wet scrubbers |
| |
Authors: | Pilat Michael J Lukas John C |
| |
Affiliation: | Department of Civil and Environmental Engineering, University of Washington, Seattle, Washington 98195, USA. mpilat@u.washington.edu |
| |
Abstract: | Water droplet charge/mass of wet scrubbers was measured over the direct charging applied potential range of 0-20 kV, 30-70 pounds per square inch gauge (206.8-482.6 kPa) water pressure, and with spiral, impingement, and whirl nozzles. The measured charge/mass ranged from -0.0005 to 0.2 microcoulomb/gm and was directly related to the applied voltage. The water charge/mass was a function of the spray nozzle, with the smaller orifice lower-flow nozzles having the higher charge/mass. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|