4阶导数光谱法同时测定酚类及芳胺的统计性检验
引用本文:鞠美庭,袁存光,冯成武. 4阶导数光谱法同时测定酚类及芳胺的统计性检验[J]. 油气田环境保护, 1996, 6(4): 44-48
作者姓名:鞠美庭  袁存光  冯成武
作者单位:石油大学炼制系
基金项目:中国石油天然气总公司“八五”重点环保科技项目
摘    要:
介绍4阶导数光谱法同时测定污水中酚类及芳胺方法的统计性检验,通过样品加标回收实验以及F检验和t检验证明该方法的精密度和准确度均优于国家环保局推荐的4-氨基安替比林先度法删酚和萘乙二胺偶氮光度法测芳胺的实验方法。

关 键 词:酚,精度,数理统计,芳香烃

Statistical test of phenol and aryl-amine simultaneous determination with 4th derivation spectrum method
Ju Meiting, Yuan Cunguang, Feng Chengwu. Statistical test of phenol and aryl-amine simultaneous determination with 4th derivation spectrum method[J]. Environmental Protection of Oil & Gas Fields, 1996, 6(4): 44-48
Authors:Ju Meiting   Yuan Cunguang   Feng Chengwu
Abstract:
The paper introduced statistical test of phenol and aryl-amine simultaneous determination in sewage with 4th derivative spectrum. Specimen standard addition recovery experiment,F-test and t-test have been done. It is proved that the precision and accuracy is prior to the method recommended by the National Environmental Protection Bureau, which is applied to determine phenol and aryl-amine with 4-amino antypyrine method.
Keywords:phenol   accuracy   mathematical statistice   aromatic hydrocarbon