低氮燃烧器改造后再热器管屏积渣原因分析
引用本文:马文举. 低氮燃烧器改造后再热器管屏积渣原因分析[J]. 防灾减灾工程学报, 2015, 0(1): 68-71
作者姓名:马文举
作者单位:华能宁夏大坝发电有限责任公司, 宁夏 青铜峡 751607
摘    要:针对某发电厂锅炉低氮燃烧器改造后发生的高温再热器管屏积渣问题,从运行参数、 配煤方式、水平烟道吹灰器型式及受热面变形等方面进行了分析,提出了针对性的解决措施。结果表明:运行中锅炉含氧量偏低,导致炉膛出口烟温升高是造成高温再热器管屏间积渣的主要原因。

关 键 词:低氮燃烧器; 含氧量; 高温再热器; 积渣

Cause analysis of slag depositing on platen type reheater tubes after the reform of lowNox burner
MA Wenju. Cause analysis of slag depositing on platen type reheater tubes after the reform of lowNox burner[J]. Journal of Disaster Prevention and Mitigation Engineering, 2015, 0(1): 68-71
Authors:MA Wenju
Affiliation:Ningxia Daba Power Generation Co ,Ltd of Huaneng Group,Qingtongxia Ningxia 751607 ,China
Abstract:Aiming at the problem of slag depositing on platen type high temperature reheater tubesafter the reform of low -Nox burner,analyzes the operation parameters,the coal blending way,thehorizontal flue ash type and the heating surface deformation,etc.,puts forward targetedcountermeasures. The result shows that the oxygen content is low,leading to temperature to rise atthe exit of hearth is main cause of slag depositing on platen type high temperature reheater tubes.