二苯碳酰二肼光度法测定低含量CODCr
引用本文:呼晋江,兰生富,曹佳红.二苯碳酰二肼光度法测定低含量CODCr[J].四川环境,2008,27(4):20-23.
作者姓名:呼晋江  兰生富  曹佳红
作者单位:成都市城市排水监测站,成都,610063
摘    要:本文以二苯碳酰二脐光度法可测1~70mg/LCODCr,最低检出限为0,8mg/L,变异系数为6,2%,可用于污水处理厂出水、纯净水、饮用水、自来水等低含量CODCr。测定。

关 键 词:二苯碳酰二肼光度法  空白CODCr

Determination of Low Concentration CODcr by Photometry of Diphenylcarbazide
HU Jin-jiang,LAN Sheng-fu,CAO Jia-hong.Determination of Low Concentration CODcr by Photometry of Diphenylcarbazide[J].Sichuan Environment,2008,27(4):20-23.
Authors:HU Jin-jiang  LAN Sheng-fu  CAO Jia-hong
Institution:( Chengdu Municipal Drainage Monitoring Centre, Chengdu 610063, China)
Abstract:In this paper CODCr with concentration as low as 1 - 70 mg/L was test by photometry of Diphenylcarhazide with LOD and RSD as 0. 81 mg/L and 6. 2 % respectively. This technology is available to test CODCr with low concentration such as that in effluent of sewage treatment plants, pure water, drinking water and running water.