Studies on sampling methods for PCDDs and PCDFs in stack emission |
| |
Authors: | I. F ngmark, L-E Wikstr m, S. Marklund,C. Rappe |
| |
Affiliation: | I. Fängmark*, L-E Wikström, S. Marklund,C. Rappe |
| |
Abstract: | Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in stack emission exist both as vapor and sorbed onto the surface of particles. The partition between the two phases is of a dynamic nature and changes rapidly with temperature. When monitoring stack emissions, a sampling method must be used that efficiently collects both phases as well as any condensation aerosol formed in the sampling train. In this study, the two sampling methods used in Sweden, the cooled probe polyurethane foam plug (PUFP) sampling train and the sampling train recommended by the Swedish Environmental Protection Board has been tested for particle collection ability. The results show that an aerosol filter has to be introduced after the condensor in order to collect particle bound PCDDs and PCDFs efficiently. |
| |
Keywords: | PCDD PCDF sampling flue gas aerosol |
本文献已被 ScienceDirect 等数据库收录! |
|