土壤中氰化物的快速测定——以江苏镇江电镀园区土壤监测为例 |
| |
引用本文: | 殷伟庆,郭蕾,黄莹,谢兵,戴舒雅. 土壤中氰化物的快速测定——以江苏镇江电镀园区土壤监测为例[J]. 干旱环境监测, 2014, 0(2): 70-74 |
| |
作者姓名: | 殷伟庆 郭蕾 黄莹 谢兵 戴舒雅 |
| |
作者单位: | 镇江市环境监测中心站,江苏镇江212004 |
| |
摘 要: | 以电镀园区为例,利用流动注射仪对园区土壤中的氰化物进行了快速测定,并与传统分光光度法进行了比对.结果表明:流动注射法中准确度和精密度均满足监测要求;pH为3.8、蒸馏温度为125℃是氰化物测定的最佳实验条件;流动注射法和传统方法测试的结果相对标准偏差(RSD)均小于8%.该法具有分析速度快、稳定性好等特点,适用于大批量土壤样品测定.
|
关 键 词: | 流动注射 土壤 电镀园区 氰化物 |
The Rapid Determination of Cyanide in Soil by Flow Injection Technique |
| |
Affiliation: | YIN Wei- qing, GUO Lei, HUANG Ying, XIE Bing, DAI Shu -ya (Zhenjiang Environmental Monitoring Centre Station, Zhenjiang Jiangsu 212004 ,China) |
| |
Abstract: | A rapid determination of cyanide in electroplating park soil by flow injection technique which was compared with traditional speetrophotometry was reported. It was found that both the accuracy and precision could meet the monitoring requirement. The best experimental conditions of total cyanide were pH 3.8 and the distillation temperature was 125℃. The relative standard deviation hetween flow injection and traditional technique was less than 8% respectively. This technique has the advantage of fast speed and good stability which is suitable for determining of mass soil samples. |
| |
Keywords: | flow injection soil electroplating park cyanide |