Asbestos exposure among Seoul metropolitan subway workers during renovation of subway air-conditioning systems |
| |
Authors: | Yu Il Je Yoo Chan Young Chung Yong Hyun Han Jeong Hee Yhang Sook Young Yu Gye Mook Song Kyung Seuk |
| |
Affiliation: | Korea Occupational Safety and Health Agency, 104-8 Munji-dong, Yuseong-gu, 305-380 Daejeon, South Korea. u1670916@chollian.net |
| |
Abstract: | Air quality in underground spaces has seldom been evaluated in Korea. Accordingly, the current study recently evaluated asbestos exposure among Seoul metropolitan subway workers during the renovation of the subway's air-conditioning system. To identify possible routes of asbestos exposure, suspected sources, including gaskets, ceiling boards, ceiling materials, and dust settled inside ducts, were all sampled. Personal air samples were also taken to evaluate any asbestos exposure during the renovation. The asbestos fibers found in the samples were analyzed using a transmission electron microscope (TEM) equipped with an energy dispersive X-ray analyzer (EDX). Twelve out of eighteen bulk samples contained asbestos, the majority of which was chrysotile fibers. Asbestos was detected in 9 out of 72 personal air samples and the level ranged from 0.003 to 0.02 fibers/cm(3). While asbestos levels were below Korean occupational limit of 2 fibers/cm(3), they were still detectable and therefore further monitoring would be appropriate. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|