摘    要:主要研究了测定波长、工作电流、燃烧器高度、光谱通带、燃气与助燃气流量等操作条件对测定工业污水中铅含量的影响 ,确定了最佳的测试条件。

关 键 词:  原子吸收光谱法  操作条件

RESEARCH ON OPTIMUM OPERATIONG CONDITIIONS OF DETERMININING LEAD IN WASTEWATER BY ATOMIC ABSORPTION SPECTROMETRY
Sun Jingzhang.RESEARCH ON OPTIMUM OPERATIONG CONDITIIONS OF DETERMININING LEAD IN WASTEWATER BY ATOMIC ABSORPTION SPECTROMETRY[J].Environmental Engineering,2004,22(4):53-55.
Authors:Sun Jingzhang
Institution:Sun Jingzhang
Abstract:It is studied mainly that the effects of the opeating conditions,such as the measured wavelength,working current,height of burner,spectrum bandpass and flow of combustion gas etc on the determination of lead content in industrial sewage.Based on which the optimum testing conditions are also determined.