首页 | 本学科首页   官方微博 | 高级检索  
     

ACCU采样和PIXE技术用于PM10污染溯源的研究
引用本文:张元勋,李德禄,李爱国,·陆文忠,王荫淞,李燕,张桂林,张元茂,郑叶飞,山祖慈,韩婷,丁文斌. ACCU采样和PIXE技术用于PM10污染溯源的研究[J]. 环境科学学报, 2005, 25(2): 155-159
作者姓名:张元勋  李德禄  李爱国  ·陆文忠  王荫淞  李燕  张桂林  张元茂  郑叶飞  山祖慈  韩婷  丁文斌
作者单位:1. 中国科学院上海应用物理研究所,上海,201800
2. 上海市环境监测中心,上海,200030
3. 上海市宝山区环境监测站,上海,200940
基金项目:中国科学院知识创新工程重要方向性项目(KJCX2-SW-N01)
摘    要:使用美国RP公司生产的多通道自动采样系统(ACCU)在上海吴淞工业区进行冬季3个月8个不同风向的PM10采样;使用质子激发X荧光发射方法(PIXE)测定颗粒物中18个无机元素浓度.结果发现,8个风向的质量浓度分布取决于不同方位的大气质量状况.将大气颗粒物中的元素浓度作为环境污染指纹,8个方位的无机元素浓度分布与采样点周围的居民住宅、道路交通和工矿企业的排放密切相关,表明该方法能准确地确定排放源的范围和污染来源.研究结果表明,ACCU采样系统和PIXE分析技术的优化组合可为大气污染溯源、治理和改善环境空气质量提供一种快速和准确可靠的新方法.

关 键 词:PM10污染 大气颗粒物 大气污染 排放源 大气质量 环境污染 污染来源 无机元素 法能 RP
文章编号:0253-2468(2005)01-0155-05
收稿时间:2004-03-28
修稿时间:2004-03-28

Source identification of PM10 aerosol samples by ACCU sampler and PIXE technique
ZHANG Yuanxun,LI Delu,LI Aiguo,LU Wenzhong,WANG Yinsong,LI Yan,ZHANG Guilin,ZHANG Yuanmao,ZHENG Yefei,SHAN Zuci,HAN Ting and DING Wenbin. Source identification of PM10 aerosol samples by ACCU sampler and PIXE technique[J]. Acta Scientiae Circumstantiae, 2005, 25(2): 155-159
Authors:ZHANG Yuanxun  LI Delu  LI Aiguo  LU Wenzhong  WANG Yinsong  LI Yan  ZHANG Guilin  ZHANG Yuanmao  ZHENG Yefei  SHAN Zuci  HAN Ting  DING Wenbin
Affiliation:Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800,Shanghai Environmental Monitoring Center, Shanghai 200030,Shanghai Environmental Monitoring Center, Shanghai 200030,Shanghai Environmental Monitoring Center, Shanghai 200030,Shanghai Environmental Monitoring Station of Bao Shan District, Shanghai 200940 and Shanghai Environmental Monitoring Station of Bao Shan District, Shanghai 200940
Abstract:The samples of PM_(10) inhalable particulate matter with eight directions of wind had been collected at a representative site of Wu Song industrial district in Shanghai in winter using Automated Cartridge Collection Unit (ACCU) of Rupprecht & Patashnick Co. The samples were analyzed to determine the average concentrations of eighteen elements by means of the Proton Induced X-ray Emission (PIXE). The results showed that the mass distribution of particulate matter in different directions depends on the environmental air quality. As the elemental fingerprint study of environmental pollution, spatial variation of elemental concentrations was closely related with the residential dense, the vehicle traffic, and the exhausts of refineries, chemicals and steel factories around the sampling site. It was demonstrated that the excellent combination of ACCU sampler and PIXE technique provided a fast and accurate means for environmental source detected.
Keywords:PM_(10)  ACCU  PIXE  elemental concentration  source identification
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《环境科学学报》浏览原始摘要信息
点击此处可从《环境科学学报》下载全文