首页 | 本学科首页   官方微博 | 高级检索  
     检索      

固定化条件对苯系物细胞传感器检测效果的影响
引用本文:唐阔,马安周,于清,邓雪梅,吕迪,庄国强.固定化条件对苯系物细胞传感器检测效果的影响[J].环境科学,2013,34(2):760-766.
作者姓名:唐阔  马安周  于清  邓雪梅  吕迪  庄国强
作者单位:中国科学院生态环境研究中心中科院环境生物技术重点实验室(筹),北京,100085
基金项目:中国科学院知识创新工程重要方向项目(KSCX2-YW-JS401);国家高技术研究发展计划(863)项目(2007AA06A407);国家科技支撑计划项目(2012BAJ24B02);中国科学院知识创新工程重要方向项目(KSCX2-YW-G-072)
摘    要:利用海藻酸钠作为包埋剂对苯系物细胞传感器Pseudomonas fluorescens A506(pTS)进行固定化处理,并对细胞浓度、固定化时间、投加量等检测因素进行了优化.固定化后的细胞与游离细胞对苯系污染物的检测效果进行对比.经过2 h固定化处理的细胞传感器,在检测时间1.5~6.0 h内,信号上升速度为游离细胞的2.26倍,信号最大值为游离细胞的2.23倍.固定化处理后的细胞生长缓慢,且浓度远低于游离细胞,说明了固定化处理后的单位细胞信号强度增加.同时,细胞浓度随着固定化时间的延长而降低.在影响因素方面,细胞浓度和固定化时间对于检测信号的影响较大.固定化后,对高浓度的苯系污染物有着更快的信号响应.

关 键 词:苯系物检测  固定化细胞  细胞浓度  固定化时间  投加量
收稿时间:2012/5/16 0:00:00
修稿时间:2012/9/12 0:00:00

Effect of Immobilization on Biosensor for Benzene Derivates Detection
TANG Kuo,MA An-zhou,YU Qing,DENG Xue-mei,LV Di and ZHUANG Guo-qiang.Effect of Immobilization on Biosensor for Benzene Derivates Detection[J].Chinese Journal of Environmental Science,2013,34(2):760-766.
Authors:TANG Kuo  MA An-zhou  YU Qing  DENG Xue-mei  LV Di and ZHUANG Guo-qiang
Institution:Key Laboratory of Environmental Biotechnology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085,China;Key Laboratory of Environmental Biotechnology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085,China;Key Laboratory of Environmental Biotechnology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085,China;Key Laboratory of Environmental Biotechnology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085,China;Key Laboratory of Environmental Biotechnology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085,China;Key Laboratory of Environmental Biotechnology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences,Beijing 100085,China
Abstract:A whole cell sensor, Pseudomonas fluorescens A506(pTS), was immobilized by sodium alginate and the factors of cell density, immobilization time and beads usage were optimized. The performance of the immobilized cells was compared with that of the free cells. After 2 h immobilization,the increasing speed of fluorescent signal of immobilized cells was 2.26 times as high as that of the free cells,and the peak value was 2.23 times as high during the detection time ranging from 1.5 to 6.0 h. The constantly lower growth and density of the immobilized cell implied the enhanced signal intensity of single cells after immobilization. Meanwhile, the cell density decreased as the immobilization time prolonged. Cell density and immobilization time were the dominant factors affecting the detection signal. For benzene at higher concentrations, the immobilized biosensor showed more rapid signal response at the early period of detection.
Keywords:benzene derivates detection  immobilized cell  cell density  immobilization time  beads usage
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《环境科学》浏览原始摘要信息
点击此处可从《环境科学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号