摘    要:以无锡芦村污水处理厂四期曝气池为研究背景,采用尾气法测定了微孔曝气头在实际污水厂正常运行工况下的充氧性能参数,与理论清水中该值比较,评价曝气头运行情况.结果表明,在污水处理厂曝气池不同廊道分布的曝气头氧传质性能存在显著差异,同一廊道的曝气头在一天内的氧传质能力变化不大.与清水条件相比,实际工况下曝气池中的微孔曝气头充氧性能下降较大,其中氧传质系数KLa、充氧能力OC和氧利用率Ea分别下降了43%、57%和76%.

关 键 词:微孔曝气头  工况  尾气法  氧传质系数  充氧能力  氧利用率
收稿时间:2012/2/15 0:00:00
修稿时间:2012/7/22 0:00:00

Measurement and Analysis of Micropore Aeration System's Oxygenating Ability Under Operation Condition in Waste Water Treatment Plant
WU Yuan-yuan,ZHOU Xiao-hong,SHI Han-chang and QIU Yong.Measurement and Analysis of Micropore Aeration System's Oxygenating Ability Under Operation Condition in Waste Water Treatment Plant[J].Chinese Journal of Environmental Science,2013,34(1):194-197.
Authors:WU Yuan-yuan  ZHOU Xiao-hong  SHI Han-chang and QIU Yong
Institution:School of Environment, Tsinghua University, Beijing 100084, China;School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China;School of Environment, Tsinghua University, Beijing 100084, China;School of Environment, Tsinghua University, Beijing 100084, China;School of Environment, Tsinghua University, Beijing 100084, China
Abstract:Using the aeration pool in the fourth-stage at Wuxi Lucun Waste Water Treatment Plant (WWTP) as experimental setup, off-gas method was selected to measure the oxygenating ability parameters of micropore aerators in a real WWTP operating condition and these values were compared with those in fresh water to evaluate the performance of the micropore aerators. Results showed that the micropore aerators which were distributed in different galleries of the aeration pool had significantly different oxygenating abilities under operation condition. The oxygenating ability of the micropore aerators distributed in the same gallery changed slightly during one day. Comparing with the oxygenating ability in fresh water, it decreased a lot in the real aeration pool, in more details, under the real WWTP operating condition, the values of oxygen transfer coefficient KLa, oxygenation capacity OC and oxygen utilization Ea decreased by 43%, 57% and 76%, respectively.
Keywords:microporous aerator  operation condition  off-gas method  oxygen mass transfer coefficient  oxygenating capacity  oxygen utilization ratio