首页 | 本学科首页   官方微博 | 高级检索  
     检索      

回灌对垃圾填埋初期渗滤液化学需氧量的影响
引用本文:邹庐泉,何品晶,邵立明,李国建.回灌对垃圾填埋初期渗滤液化学需氧量的影响[J].环境污染与防治,2004,26(4):241-243.
作者姓名:邹庐泉  何品晶  邵立明  李国建
作者单位:同济大学,污染控制与资源化研究国家重点实验室,上海,200092;同济大学,污染控制与资源化研究国家重点实验室,上海,200092;同济大学,污染控制与资源化研究国家重点实验室,上海,200092;同济大学,污染控制与资源化研究国家重点实验室,上海,200092
基金项目:国家“十五”863计划课题资助项目 ( 2 0 0 1AA64 40 10 ),上海市重点学科 (环境工程专业 )建设资助项目
摘    要:通过模拟柱实验 ,研究了回灌对垃圾填埋场初期渗滤液 CODCr的影响。研究结果表明 ,模拟降雨雨水的渗入且无渗滤液回灌的参照柱 ,其渗滤液出水 CODCr最高 ,一般在 70 0 0 0 mg/L 左右 ;模拟渗滤液原液回灌 ,从第 4周起因脂肪酸的积累导致渗滤液的 p H低于 6,从而抑制了微生物的生化反应 ;模拟好氧生物处理后渗滤液的回灌 ,能加速垃圾层 CODCr的溶出和甲烷化阶段的建立 ,且此时渗滤液的 CODCr变化规律符合指数方程 ;当垃圾层建立甲烷化阶段后 ,回灌 CODCr在 2 0 0 0 0 m g/L 左右的渗滤液 ,仍可促使垃圾中有机物迅速转化为气态物

关 键 词:生活垃圾  填埋  回灌方式  渗滤液  CODcr

Influence of recirculation operations on chemical oxygen demand of leachate in the initial landfill stage
Zou Luquan He Pinjing Shao Liming Li Guojian.Influence of recirculation operations on chemical oxygen demand of leachate in the initial landfill stage[J].Environmental Pollution & Control,2004,26(4):241-243.
Authors:Zou Luquan He Pinjing Shao Liming Li Guojian
Abstract:The influence of recirculation operations on chemical oxygen demand (COD Cr ) of leachate in the initial landfill stage was studied through simulation columns experiment. The experimental results indicated that the COD Cr value in the outlet of leachate of the reference column, which simulated the infiltration of runoff without leachate recirculation, was the highest around 70,000 mg/L. Microorganism metabolism was restrained when the pH value was under 6 as a result of fatty acid accumulation in the column after 4th week with direct recirculation of non\|pretreatment leachate. The recirculation of aerobic\|treated leachate, accelerated the dissolution of the materials which was shown as COD Cr and start\|up of the methane\|producing phase in the landfill. In this case, the change of COD Cr with time could be expressed with exponential equation. After the methane\|producing phase in the landfill had been set up, the transformation of the organic matter from solid to gaseous state was still accelerated by the recirculation of leachate with the COD Cr value around 20,000 mg/L.
Keywords:Municipal solid waste (MSW)  Landfill  Recirculation operations  Leachate  COD    Cr
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号