首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Fenton试剂法降解餐厨垃圾异味
引用本文:狄彦强,刘杰民,刘思园,颜鲁春,冯振华.Fenton试剂法降解餐厨垃圾异味[J].环境工程学报,2013,7(4):1445-1450.
作者姓名:狄彦强  刘杰民  刘思园  颜鲁春  冯振华
作者单位:1. 北京科技大学化学与生物工程学院,北京100083;中国建筑科学研究院,北京100013
2. 北京科技大学化学与生物工程学院,北京,100083
基金项目:国家自然科学基金资助项目(20877008,21277011);新世纪优秀人才支持计划资助(NCET-09-0218);中央高校基础科研业务费(FRF-TP-10-004B, FRF-BR-11-017B);国家高技术研究发展计划(863)项目(2012AA030302);北京市自然科学基金资助项目(8092021)
摘    要:自行设计Fenton试剂法降解还原性气体异味的反应器,研究了Fenton试剂法处理餐厨垃圾异味主要成分(苯、乙酸乙酯、苯乙烯)的降解效果。以苯为典型代表物,优化得出该实验的最佳反应条件为:pH=3,FeSO4.7H2O投加量为1 g/L液相,30%H2O2投加量为10 mL/L液相,紫外光源辅助。结果证明,Fenton试剂法处理单一异味气体的效果较理想,在前180 min内能达到90%以上,该法在处理气态异味污染物方面具有广阔的应用前景。

关 键 词:餐厨垃圾  Fenton  异味降解  氧化还原  H2O2

Treating food waste odor by Fenton reagent method
Di Yanqiang,Liu Jiemin,Liu Siyuan,Yan Luchun and Feng Zhenhua.Treating food waste odor by Fenton reagent method[J].Techniques and Equipment for Environmental Pollution Control,2013,7(4):1445-1450.
Authors:Di Yanqiang  Liu Jiemin  Liu Siyuan  Yan Luchun and Feng Zhenhua
Institution:1. Chemical and Biological Engineering Institute,University of Science and Technology Beijing,Beijing 100083, China;2. China Academy of Building Reasearch,Beijing 100013, China;1. Chemical and Biological Engineering Institute,University of Science and Technology Beijing,Beijing 100083, China;1. Chemical and Biological Engineering Institute,University of Science and Technology Beijing,Beijing 100083, China;1. Chemical and Biological Engineering Institute,University of Science and Technology Beijing,Beijing 100083, China;1. Chemical and Biological Engineering Institute,University of Science and Technology Beijing,Beijing 100083, China
Abstract:In order to reduce the odor in food waste facilities with the major components of benzene,ethyl acetate,styrene, Fenton reagent reactor was utilized in this process and corresponding parameters were optimized by single factor experiment. Benzene was chosen as the representative of food waste odor,and the parameters were determined as follows: pH of 3,the input amount of FeSO4·7H2O of 1 g/L liquid,the addition for 30% H2O2 of 10 mL/L liquid,and the UV assisted as well.The results demonstrated that Fenton reagent method could reach a better effect on the degradation of a single odor with a removal efficiency more than 90% in the first 180 min.The method could have better prospects in dealing with the gaseous odor pollutants.
Keywords:food waste  Fenton  odor degradation  redox  H2O2
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《环境工程学报》浏览原始摘要信息
点击此处可从《环境工程学报》下载免费的PDF全文