首页 | 本学科首页   官方微博 | 高级检索  
     检索      


FF/C Scrubber Demonstration on a Secondary Metals Recovery Furnace
Authors:Seymour Calvert  Shamim Gandhi  Dale L Harmon  Leslie E Sparks
Institution:1. Air Pollution Technology, Inc;2. U.S. Environmental Protection Agency
Abstract:A flux force/condensation (FF/C) scrubbing system was built to control participate emissions from a secondary metals recovery furnace. Total mass penetration and fractional penetration measurements were made under several different operating modes. The performance of the demonstration scrubber was consistent with the results of previous studies on FF/C scrubbing. The system was generally capable of 90 to 95 % efficiency on particles with a mass median aerodynamic diameter of 0.75 µA. This efficiency was achieved with a 68 cm (27 in.) W.C. gas-phase pressure drop.