Sulfur Dioxide Removal and Recovery from Pulp Mill Power Plants
Authors:S F Galeano  CI Harding  
Institution:1. Process &2. Development Engineer , Owens Illinois Inc Technical Center , Toledo , Ohio , USA;3. Assistant Professor, Air Pollution Research Laboratory , University of Florida , Gainesville , Fla. , USA
Abstract:The use of soda ash liquor to scrub SO2 rich power plant flue gases was studied using an Airetron pilot scrubber with a maximum capacity of 3000 cfm. The relative effects of the major operating variables— temperature, soda ash concentration, and the gas/liquid flow ratio—on the absorption phenomenon were determined. Orthogonal factorial experiments were used to derive a response function relating mass transfer values to operating variables. The economics of a full scale NSSC installation are discussed.