首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Quench Tower Particulate Emissions
Authors:Gerald L Ertel
Institution:Environmental Engineer , Dominion Foundries and Steel, Limited , Hamilton , Ontario , Canada
Abstract:Particulate emission sampling was conducted at Dofasco’s No. 2 Coke Want Quench Tower in August 1977. The sampling was performed by York Research Corporation using EPA developed quench tower sampling techniques. Particulate emissions averaged 0.245 lb/ton of coal over 17 tests. The mist eliminator in the tower consists of two rows of zig-zag baffles inclined at 20° from the vertical. Particle size data indicated that the majority of the particulate emissions were less than 10 microns in diameter. A mathematical model was used to predict the effect of particle size and gas velocity on collection efficiency. Pressure drop and re-entrainment are two restrictions which are considered in baffle design. Quench towers are the largest contributor to Dofasco’s allowable off-the-property suspended particulate impingement concentration.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏