Air Pollutant Emissions from Coal-Fired Power Plants,Report No. 2
Authors:R W Gerstle  S T Cuffe  A A Orning  C H Schwartz
Institution:1. Division of Air Pollution, Public Health Service, U. S. Department of Health, Education, and Welfare, Robert A. Taft Sanitary Engineering Center , Cincinnati , Ohio , USA;2. Pittsburgh Coal Research Center, Bureau of Mines, U. S. Department of the Interior , Pittsburgh , Pennsylvania , USA
Abstract:The Public Health Service and the Bureau of Mines are conducting a joint study to evaluate a number of flue-gas-stream components from coal-burning power plants. Emissions of fly ash, sulfur oxides, nitrogen oxides, polynuclear hydrocarbons, total gaseous hydrocarbons, formaldehyde, certain metals, and carbon dioxide are determined. A previous paper covered air pollutant emissions from vertical-fired and front-wall-fired power plant boilers. This paper includes a comparative evaluation of emissions from a tangential-fired and a turbo-fired power plant boiler.