Plans For APCA’s 53rd Meeting Shaping Up As May Date Nears
Authors:Dennis C Drehmel
Institution:U. S. Environmental Protection Agency
Abstract:A continuous method for the measurement of SO2 in ambient air at trace levels is described. The principle of detection is based on the anodic oxidation of SO2 in a galvanic cell. A differential measuring technique with a cell with two anodes and one cathode is used; background and noise current are low and stable. A feature of the measuring system is that the air sample is passed through a porous anode against a head of electrolyte on the other side of the anode. The minimum values for the time constant and the lower detection limit were 3 seconds and about 3µg/m3, respectively. The selectivity of the method was compared with those of other techniques in field testing. Trace concentrations measured by the galvanic method in the range from 12 to 135 µg/m3 were in good agreement with those of the flame photometric and the West-Gaeke method. With a Pt/Ni2B/graphite anode the mean oxidation efficiency was 94 ± 2% on the basis of 2 faraday/mol of SO2 within the tested concentration range of 50 to 560 µg/m3. During a field test no decrease in the anode activity was observed over a period of ten months. Examples are given for the galvanic detection of other compounds using porous measuring electrodes.