The Annual Average: An Alternative to the Second Highest Value as a Measure of Air Quality
Authors:Ronald D Snee  John M Pierrard
Institution:1. E. I. du Pont de Nemours &2. Co
Abstract:It is common practice to use the second highest value both in determining compliance with the once-per-year air quality standards (AQS) and as a measure of air quality in pollutant trend studies and rollback calculations. A study of the variation in the second highest 8 hr carbon monoxide concentration observed at the CAMP stations 1962-72 is presented. It is shown that, for a given annual average, the second highest value can differ by a factor of 2 due to random variation. The annual average is linearly related to the observed average of the second highest value and is shown to be a good predictor of the percent of time the carbon monoxide AQS is exceeded. It is concluded that the annual average, which is less variable and not as greatly influenced by erroneous measurements, is the preferred measure of air quality for trend studies and air quality projections.