首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An Evaluation of Catalytic and Direct Fired Afterburners for Coffee and Chicory Roasting Odors
Authors:J L Sullivan  F L Kafka  L M Ferrari
Institution:1. Principal Engineer, Air Pollution Control Branch, New South Wales, Department of Public Health;2. Chemical Engineer, Air Pollution Control Branch, New South Wales, Department of Public Health;3. Chemist, Air Pollution Control Branch, New South Wales, Department of Public Health
Abstract:Though the aroma of roasting coffee can be pleasant in small amounts, large scale plants tend to cause public complaints. As a means of control thermal afterburners operating at 1200°F and higher have been commonly employed. Australian coffee consumption in the past has been relatively small but in recent years it has been increasing markedly. As a result, odor complaints have been increasing and one plant, large by Australian standards, caused a public outcry of no small order. High cost of fuel rendered thermal afterburning unattractive and, consequently, the firm in question decided upon catalytic combustion as an alternative. Subsequently, the unit was installed and before and after tests were made for various components. At an operating temperature of about 700°F the results showed comparable fume reductions to thermal afterburning and the findings were confirmed by the cessation of complaints by the public.