Empirical Estimation of Virtual Point Source Height Over a Bank of Coke Ovens |
| |
Authors: | Jacek Żeliński Dorota Kaleta Jolanta Telenga-Kopyczyńska |
| |
Affiliation: | 1.Institute for Chemical Processing of Coal,Zabrze,Poland;2.Department of Air Protection,Silesian University of Technology,Gliwice,Poland |
| |
Abstract: | This paper addresses an empirical method of assessment of the height of a virtual point source. In order to achieve such assessment, three planes defining the location of a virtual point source in a space are created and formulas describing the geometry of observer’s sight and plume orientation are used. Data for calculations are obtained on a basis of plume photographs. The final position of a virtual emission point is described by a set of its coordinates in the Cartesian coordinate system. Presented method may be applied as a means to verify and validate the existing formulas describing the rise of plume above the stack exit or as a tool enabling acquisition of information for the sake of creating new formulas of this type. The calculation of the location of a virtual point source ascribed to the point emission from the roof of the bank of coke oven is presented and illustrated with photographs which reveal position of plume, adequate planes, axes and characteristic objects. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|