Quantification of indoor VOCs in twenty mechanically ventilated buildings in Hong Kong
Institution:1. Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, Singapore, 637141, Singapore;2. Environmental Health Institute NEA, 11 Biopolis Way, Singapore, 138667, Singapore;3. School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore;4. Department of Civil Engineering, Monash University, 23 College Walk, Clayton, Victoria, 3800, Australia;5. Analytics Cluster, Nanyang Environment and Water Research Institute, Nanyang Technological University, Singapore, 1 Cleantech Loop, CleanTech One, Singapore;1. Lyles School of Civil Engineering, Purdue University, West Lafayette, IN, 47907, United States;2. Colorado Department of Public Health and Environment, Denver, CO, 80246, United States;3. O''Neill School of Public and Environmental Affairs, Indiana University, Bloomington, IN, 47405, United States;4. Department of Chemistry, Indiana University, Bloomington, IN, 47405, United States;5. RJ Lee Group Inc., Monroeville, PA, 15146, United States;6. Edelweiss Technology Solutions, LLC, Novelty, OH, 44072, United States
Abstract:Information of volatile organic compounds (VOCs) in buildings in Hong Kong is relatively scared compared to other countries. Information of how much VOC accumulation comes from occupants themselves, from building materials and other outdoor sources are scarce even on a global basis. This study aimed at collecting information of the levels of individual VOCs using US-EPA Method TO-14. Twenty building premises including offices and public places such as customer service centers, shopping centers, etc. were studied. Samples were taken during the time slots when the mechanical ventilation system was operating. The 43 VOCs were grouped into three categories, i.e. aromatic hydrocarbons, chlorinated hydrocarbons and organohalogen. The most dominant VOCs found in the indoor samples were benzene, toluene, ethylbenzene, xylenes (BETX), chloroform and trichloroethylene as 100% of the samples were found to contain these VOCs. Besides, more than 75% of the samples were found to contain 1,3,5-trimethylbenzene, methylchloride and dichloromethane. The wt% of chlorinated hydrocarbons (48%) and the wt% of aromatic hydrocarbons (38%) only differed by about 10% in the office sector. Organohalogen (14%) contributed to the smallest fraction of the total on all the premises in the office sector on weight basis. A completely different distribution pattern was found in the non-office sector. The most abundant class of VOCs in terms of weight was aromatic hydrocarbons (80%). The second abundant class of VOCs was chlorinated hydrocarbons (14%) and was much less than the level of aromatic hydrocarbons in terms of weight. Organohalogen (6%) contributed to the smallest fraction of the total on all the premises in the non-office sector on weight basis.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号