首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Membrane fouling control by ultrasound in an anaerobic membrane bioreactor
Authors:Sui Pengzhe  Wen Xianghua and Huang Xia
Institution:(1) State Key Laboratory of Environment Simulation and Pollution Control, Department of Environmental Science and Engineering, Tsinghua University, Beijing, 100084, China
Abstract:In this study, ultrasound was used to control the membrane fouling online in an anaerobic membrane bioreactor (AMBR). Short-term running experiments were carried out under different operating conditions to explore feasible ultrasonic parameters. The experimental results indicated that when the crossflow velocity was more than 1.0 m/s, membrane fouling could be controlled effectively only by hydrodynamic methods without ultrasound. When ultrasound was applied, an ultrasonic power range of 60–150 W was suitable for the membrane fouling control in the experimental system. The experimental results showed that the membrane fouling was controlled so well that membrane filtration resistance (ΣR) could stay at 5 × 1011 m−1 for more than a week with the crossflow velocity of 0.75 m/s, which equaled the effect of crossflow velocity of more than 1.0 m/s without ultrasound. Translated from Techniques and Equipment for Environmental Pollution Control, 2006, 7(4): 25–29 译自: 环境污染治理技术与设备]
Keywords:anaerobic membrane bioreactor  membrane fouling control  ultrasound
本文献已被 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏