首页 | 本学科首页   官方微博 | 高级检索  
     检索      


National monitoring of PCDD/DFs in environmental media around incinerators in Korea
Authors:Kim Kyoung-Soo  Shin Sun-Kyoung  Kim Kyoung-Sim  Song Byung-Joo  Kim Jong-Guk
Institution:Department of Environmental Engineering, Cheongju University, 36 Naeduck-dong Sangdang-gu Cheongju, Chungbuk, 360-764, Republic of Korea.
Abstract:To examine the levels of PCDD/DFs pollution in environmental samples in the vicinity of various incinerators, the levels of PCDD/DFs in air and soil samples collected near 17 incinerators and stack emission gases were investigated between 2003 and 2006. A total of 434 soil, 28 stack emission gas, and 38 air samples were analyzed for their PCDD/DFs concentrations. The PCDD/DFs concentrations in the flue gas samples ranged from 0.02 to 16.41 ng I-TEQ/Sm(3), with an arithmetical mean value of 3.13 ng I-TEQ/Sm(3). The PCDD/DFs concentrations in the air samples ranged from 0.032 to 0.965 pg I-TEQ/Sm(3). The soil samples contained between N.D. and 153.23 pg I-TEQ/g-dry, with an average of 7.36 pg I-TEQ/g-dry. These levels were generally consistent with or lower than many previous studies. The average PCDD/DFs levels in the soil samples decrease with increasing distance from the incinerator. From the PCDD/DFs level gradient from each plant, a distance of 500 m is suggested as being under the influence of an incinerator.
Keywords:
本文献已被 PubMed 等数据库收录!