首页 | 本学科首页   官方微博 | 高级检索  
     检索      

气相色谱法测定工业废水中的氯代苯类
引用本文:包志成,赵倩雪.气相色谱法测定工业废水中的氯代苯类[J].环境科学学报,1983,3(4):352-356.
作者姓名:包志成  赵倩雪
作者单位:中国科学院环境化学研究所 (包志成),中国科学院环境化学研究所(赵倩雪)
摘    要:本文提供了测定工业废水中12种氯苯的简便方法:ECD-GC法.水样用石油醚萃取、经硅胶柱净化,使氯苯与六六六、DDT等完全分离.采用SF-96改性的有机皂土填充柱,可在恒温下将12个氯苯完全分离.当水中氯苯浓度在10mg/250ml(一氯苯)和0.00126mg/250ml(1,2,3,5-四氯苯)之间时,方法的回收率为93.5%.最大相对标准偏差小于4%.

收稿时间:2/2/1983 12:00:00 AM

GAS CHROMATOGRAPHIC DETERMINATION OF CHLOROBENZENES IN INDUSTRIAL WASTEWATER
Bao Zhicheng and Zhao Qianxue.GAS CHROMATOGRAPHIC DETERMINATION OF CHLOROBENZENES IN INDUSTRIAL WASTEWATER[J].Acta Scientiae Circumstantiae,1983,3(4):352-356.
Authors:Bao Zhicheng and Zhao Qianxue
Institution:Institute of Environmental Chemistry, Academia Sinica, Beijins and Institute of Environmental Chemistry, Academia Sinica, Beijins
Abstract:A gas chromatographic method for determination of chlorobenzenes in wastewater was described. A water sample (250ml) was transferred into a 500ml separatory funnel and extracted with 25ml petroleum ether. An extract of 3ml was passed through a silica column containing 3g activated silica gel and a 2cm-layer of anhydrous sodium sulfate. Column was then eluted with 10ml petroleum ether. 8ml eluate was collected and analyzed by ECD gas chromatography. Bentone-34 modified with SF-86 on 80-100 mesh Chromosorb W. HP was used for column packing. All of the 12 chlorobenzenes were completely separated. The mean recovery for high and low level chlorobenzenes was 93.5% and the maximum relative standard deviation was less than 4 %. Elution conditions for chlorobenzenes in presence of BHC and DDT were presented and MDLs for each chlorobenzene were also examined. The method described here possesses great advantage over others to analysis of chlorobenzene mixtures. It has been successfully applied to determination of chlorobenzenes in industrial wastewater as well.
Keywords:
本文献已被 CNKI 等数据库收录!
点击此处可从《环境科学学报》浏览原始摘要信息
点击此处可从《环境科学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号