Evaluation of the George Neal electrostatic precipitator
Authors:Robert C Carr  David S Ensor
Abstract:The Electric Power Research Institute (EPRI) is currently supporting a major research program characterizing the performance of high efficiency electrostatic precipitators (ESP). One such effort evaluating the George Neal ESP of Iowa Public Service Company is described in this paper.Results show that under well tuned conditions the ESP overall collection efficiency was 99.7% at a specific collecting area of 745 ft2/kacfm (147 m2/m3/s) (520 MW) with associated mass concentrations of 0.025 lb/106 Btu and stack opacity of 4.6%. The boiler outlet size distribution was found to be bimodal with submicron and large particle peaks at 0.2 and 5 microns diameter, respectively. Consequently, an apparent bimodal fractional efficiency curve results with efficiencies of 99.6%, 98%, and 90% measured for 20, 2 and 0.2 micron diameter particles, respectively. Rapping reentrainment losses were found to be insignificant except during episodes of high ash hopper levels resulting from a malfunctioning ash removal system, when large rapping puffs were observed. In addition, outlet emissions increased dramatically to 0.08 lb/106 Btu (34 ng/J) during these periods, suggesting that an emission level more representative of daily operation lies somewhere between 0.025–0.08 lb/106 Btu (10.8–34 ng/J).