摘    要:
由于具有强腐蚀性,海水淡化水在既有市政管网输配过程中往往会产生严重的"红水"现象,主要是由于管网中铁的释放.为了研究控制既有管网中铁释放的有效措施,对管龄为30~40 a的钢管和灰口铸铁管内壁的腐蚀瘤进行分析,主要组成物质为Fe3O4和FeOOH;选择腐蚀较严重的钢管进行静态浸泡试验,重点分析了自来水和淡化水的掺混比、pH值、碱度、氯离子和硫酸根离子对铁释放的影响,并以铁浓度为控制量,初步给出了海水淡化水在既有管网中安全输配所需满足的水质条件:自来水和淡化水的掺混比≥2∶1,pH值在7.6以上,碱度>200 mg.L-1.

关 键 词:海水淡化水  安全输配  铁释放  水质指标  钢管  浸泡试验
收稿时间:2011-05-18
修稿时间:2011-08-18

Research on Controlling Iron Release of Desalted Water Transmitted in Existing Water Distribution System
TIAN Yi-mei,LIU Yang,ZHAO Peng,SHAN Jin-lin,YANG Suo-yin and LIU Wei. Research on Controlling Iron Release of Desalted Water Transmitted in Existing Water Distribution System[J]. Chinese Journal of Environmental Science, 2012, 33(4): 1216-1220
Authors:TIAN Yi-mei  LIU Yang  ZHAO Peng  SHAN Jin-lin  YANG Suo-yin  LIU Wei
Affiliation:School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China;School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China;School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China;School of Environmental Science and Engineering, Tianjin University, Tianjin 300072, China;Beijiang Power Plant, Tianjin 300480, China;Beijiang Power Plant, Tianjin 300480, China
Abstract:
Desalted water, with strong corrosion characteristics, would possibly lead to serious "red water" when transmitted and distributed in existing municipal water distribution network. The main reason for red water phenomenon is iron release in water pipes. In order to study the methods of controlling iron release in existing drinking water distribution pipe, tubercle analysis of steel pipe and cast iron pipe, which have served the distribution system for 30-40 years, was carried out, the main construction materials were Fe3O4 and FeOOH; and immersion experiments were carried in more corrosive pipes. Through changing mixing volume of tap water and desalted water, pH, alkalinity, chloride and sulfate, the influence of different water quality indexes on iron release were mainly analyzed. Meanwhile, based on controlling iron content, water quality conditions were established to meet with the safety distribution of desalted water: volume ratio of potable water and desalted water should be higher than or equal to 2, pH was higher than 7.6, alkalinity was higher than 200 mg·L-1.
Keywords:desalted water  safety transmitting  iron release  water quality indexes  steel pipe  immersion experiment