原油外输泵房噪声分析与防治
引用本文:赵金山,王咏梅.原油外输泵房噪声分析与防治[J].安全.健康和环境,2009,9(5):41-42.
作者姓名:赵金山  王咏梅
作者单位:中国石化胜利油田分公司东辛采油厂,山东,东营,257094;山东胜安石油科技有限公司,山东,东营,257000
摘    要:介绍了采油厂原油外输泵房的噪声现状及噪声对职工造成的危害,分析了噪声的主要来源为电磁噪声、机械噪声、空气动力l陛噪声以及阀门噪声、摩擦噪声和管路噪声等,其声压级在90~104dB之间,频率主要集中在200~3000Hz范围,并制定了噪声治理方案。

关 键 词:泵房  噪声  降噪技术

Noise Analysis of Oil Transfer Pump Station and Its Control
Zhao Jinshan,Wang Yongmei.Noise Analysis of Oil Transfer Pump Station and Its Control[J].Safety Environment Health,2009,9(5):41-42.
Authors:Zhao Jinshan  Wang Yongmei
Institution:1 SINOPEC Shengli Oilfield Sub-company Dongxin Oil Recovery Plant;Shandong;Dongying;257094 2 Shandong Sheng'an Petroleum Technological Company Ltd.;257000
Abstract:This paper introduces noise situation and its harm to the workers of oil transfer pump station in oil recovery plant. It analyzes that main noise resources are electromagnetic noise,mechanical noise, aerodynamic noise, valve noise, frictional noise and pipe noise. Its sound pressure level is 90 - 104 dB; its frequency range focus on 200 - 3 000 Hz. At last, it offers the noise control measures.
Keywords:pump station  noise  noise control technology  