Correction methods for organic carbon artifacts when using quartz-fiber filters in large particulate matter monitoring networks: the regression method and other options |
| |
Authors: | Maimone Francesco Turpin Barbara J Solomon Paul Meng QingYu Robinson Allen L Subramanian R Polidori Andrea |
| |
Affiliation: | Department of Environmental Sciences, Rutgers University, New Brunswick, NJ, USA. |
| |
Abstract: | Sampling and handling artifacts can bias filter-based measurements of particulate organic carbon (OC). Several measurement-based methods for OC artifact reduction and/or estimation are currently used in research-grade field studies. OC frequently is not artifact-corrected in large routine sampling networks (e.g., U.S. Environmental Protection Agency (EPA)'s Chemical Speciation Network). In some cases, the OC artifact has been corrected using a regression method (RM) for artifact estimation. In this method, the gamma-intercept of the regression of the OC concentration on the fine particle (PM2.5) mass concentration is taken to be an estimate of the average OC sampling artifact (net of positive and negative artifacts). This paper discusses options for artifact correction in large routine sampling networks. Specifically, the goals are to (1) articulate the assumptions and limitations inherent to the RM, (2) describe other artifact correction approaches, and (3) suggest a cost-effective method for artifact correction in large monitoring networks. The RM assumes a linear relationship between measured OC and PM mass: a constant slope (OC mass fraction) and a constant intercept (RM artifact estimate). These assumptions are not always valid. Additionally, outliers and other individual data points can have a large influence on the RM artifact estimates. The RM yields results within the range of measurement-based methods for some datasets and not for others. Given that the adsorption of organic gases increases with atmospheric concentrations of organics, subtraction of an average artifact from all samples (e.g., across multiple sites) will underestimate OC for lower-concentration samples (e.g., clean sites) and overestimate OC for higher-concentration samples (e.g., polluted sites). For relatively accurate, simple, and cost-effective artifact OC estimation in large networks, the authors suggest backup filter sampling on at least 10% of sampling days at all sites with artifact correction on a sample-by-sample basis as described herein. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|