紧急启动及停炉后增压锅炉热防护砖衬结构的强度分析 |
| |
引用本文: | 赵嘉煜,杨自春,曹跃云,李昆锋,司亚军.紧急启动及停炉后增压锅炉热防护砖衬结构的强度分析[J].中国特种设备安全,2014(10):48-54. |
| |
作者姓名: | 赵嘉煜 杨自春 曹跃云 李昆锋 司亚军 |
| |
作者单位: | 海军工程大学,武汉430033 |
| |
摘 要: | 针对船用增压锅炉在频繁启、停炉过程中,热防护砖衬结构中的耐火材料易出现的断裂、脱落等问题,采用有限元分析法对热防护砖衬结构进行强度校核,分析出现损伤的结构部件及耐火材料发生断裂的原因,对增压锅炉的安全使用与预防损坏具有一定的参考意义。
|
关 键 词: | 增压锅炉 热防护砖衬结构 温度场 应力场 强度分析 |
Strength Analysis of Thermal-protective Tiles Lining in the Supercharged Boiler under an Emergency Running and Stopping Condition |
| |
Authors: | Zhao Jiayu Yang Zichun Cao Yueyun Li Kunfeng Si Yajun |
| |
Institution: | Zhao Jiayu Yang Zichun Cao Yueyun Li Kunfeng Si Yajun (Naval University of Engineering Wuhan 430033 ) |
| |
Abstract: | To solve problems like fracture and drop of the thermal-protective materials in the thermal-protective tiles lining when the suoercharged boiler runs and stops repeatedly.This paper uses the finite element method to check the strength of the thermal-protective tiles lining,finding out the components that may appear destruction and their reasons of the fracture.We can offer the guide how to run a suoercharged boiler safely and predict destructions. |
| |
Keywords: | Supercharged boiler Thermal-protective tiles lining Temperature field Stress fieldStrength analysis |
本文献已被 维普 等数据库收录! |