首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Influence of sewage culvert cover plate thickness on dynamic response and damage of the cover plate under gas explosion
Institution:1. State Key Laboratory of Precision Measuring Technology & Instruments, Laboratory of MicroNano Manufacturing Technology, Tianjin University, Tianjin 300072, China;2. Industrial Artificial Intelligence Technology Research Center, Taiyuan Institute of Technology, Taiyuan 030008, China;3. Centre of Micro/Nano Manufacturing Technology (MNMT-Dublin), University College Dublin, Dublin 4, Ireland;4. Shanxi key laboratory of precision machining, Taiyuan University of Technology, Taiyuan 030024, China
Abstract:In order to address the risk of combustible gas explosions in sewage culverts, a numerical model was established using ANSYS/LS-DYNA software. The model consisted of a culvert and a cover plate, and was used to study the effect of cover plate thickness (ranging from 0.08 m to 0.12 m) on the dynamic response and damage of the structure under explosive loads. The results indicated that, during the loading negative pressure stage, the equivalent stress peak value of the central monitoring unit of the cover plate first increased and then decreased with increasing cover plate thickness. Additionally, the maximum principal stress peak value first decreased and then increased, while the maximum shear stress peak value first increased and then decreased. During the loading positive pressure stage, the maximum principal strain peak value of the monitoring unit decreased overall with increasing cover plate thickness. However, the equivalent plastic strain peak value initially increased and then decreased gradually. The equivalent strain indicated that plastic damage occurred in the cover plate. Beyond a thickness of 0.11 m, increasing the cover thickness did not appear to enhance its resistance to plastic damage. The damage analysis revealed that as cover plate thickness increased, the peak displacement and velocity of the monitoring unit continued to decrease, while the overall stability and explosive resistance of the cover plate increased. Additionally, the number of damaged fragments decreased. However, once the cover plate thickness reached 0.11 m, the bonding performance of the reinforced concrete structure had been fully developed, increasing the thickness of the cover plate no longer had a significant impact on the explosive resistance of the cover plate.
Keywords:Gas explosion  Sewage culvert  Structural damage  Dynamic response  Cover plate thickness
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号