首页 | 本学科首页   官方微博 | 高级检索  
     检索      

检测污水中氨氮大于总氮原因简析及改善
作者姓名:栾启夏
作者单位:上海宝钢工业技术服务有限公司宝钢环境监测站
摘    要:通常情况下同一个水样中的氨氮值应该小于总氮值,但是在实际的检测工作中常常遇到同一个水样氨氮值大于总氮的情况,基于数据与理论值的差异,本文探讨了出现这种情况的主要原因是当水样中氨氮占据总氮的绝大部分比例时,碱性过硫酸钾消解条件下,总氮中的氨氮会以氨气的形式逸散在气相中极易造成损失,并通过对比分析了改进密封性对于实验数据的改善情况。

关 键 词:总氮  氨氮  碱性过硫酸钾法

Analysis and improvement of the reason why ammonia nitrogen in wastewater is greater than total nitrogen
Authors:Luan Qixia
Institution:(Baosteel Environmental Monitoring Station,Shanghai Baosteel Industrial Technology Service Co.,Ltd.,Shanghai 201900,China)
Abstract:Generally,the ammonia nitrogen value in the same water sample should be less than the total nitrogen value.However,in the actual testing work,the same water sample ammonia nitrogen value is often greater than the total nitrogen.Based on the difference between the data and the theoretical value,this paper The main reason for the occurrence of this situation is that when the ammonia nitrogen accounts for the majority of the total nitrogen in the water sample,the ammonia nitrogen in the total nitrogen will escape in the middle of the gas phase in the form of ammonia gas under the condition of alkaline potassium persulfate digestion.It is easy to cause losses,and through comparison,the improvement of experimental data is improved by improving the sealing performance.
Keywords:Total nitrogen  Ammonia nitrogen  Alkaline potassium persulfate method
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号