首页 | 本学科首页   官方微博 | 高级检索  
     检索      

内循环(IC)厌氧反应器处理糖蜜酒精废水的研究
引用本文:邹华,魏学军,阮文权,严群,赵明星.内循环(IC)厌氧反应器处理糖蜜酒精废水的研究[J].环境工程学报,2007,1(5):41-44.
作者姓名:邹华  魏学军  阮文权  严群  赵明星
作者单位:1. 江南大学工业生物技术教育部重点实验室,无锡,214122
2. 新疆昌吉糖厂,昌吉,831100
摘    要:糖蜜酒精废水由于含有高浓度的COD和硫酸盐,一般厌氧反应器无法有效处理.研究了IC反应器处理糖蜜酒精废水的效果.考察其COD及硫酸盐的去除率、沼气的产量和组分等.结果表明,反应器对于COD为5000~10 000 mg/L的中、高浓度废水去除效果良好,当COD在20 000~30 000 mg/L时,在适应了1~2个停留时间后,去除效果达到稳定,去除率在90%左右.实验中最高容积负荷提升至40 kg COD/m3·d左右.本研究中所用的糖蜜酒精废水的COD/SO24-的平均值为61.9,未对反应器的处理效果及产气量产生影响.

关 键 词:IC  反应器  糖蜜酒精废水  硫酸盐  沼气
文章编号:1673-9108(2007)05-0041-04
修稿时间:2006-07-282007-03-20

Molasses wastewater treatment with an internal circulation (IC) reactor
Zou Hu,Wei Xuejun,Ruan Wenquan,Yan Qun and Zhao Mingxing.Molasses wastewater treatment with an internal circulation (IC) reactor[J].Techniques and Equipment for Environmental Pollution Control,2007,1(5):41-44.
Authors:Zou Hu  Wei Xuejun  Ruan Wenquan  Yan Qun and Zhao Mingxing
Institution:Key Laboratory of Industrial Biotechnology, Ministry of Education, Southern Yangtze University, Wuxi 214122,Xinjiang Changji Sugar Factory, Changji 831100,Key Laboratory of Industrial Biotechnology, Ministry of Education, Southern Yangtze University, Wuxi 214122,Key Laboratory of Industrial Biotechnology, Ministry of Education, Southern Yangtze University, Wuxi 214122 and Key Laboratory of Industrial Biotechnology, Ministry of Education, Southern Yangtze University, Wuxi 214122
Abstract:The difficulty in treating molasses wastewater is due to the high COD concentration of the wastewater which contains a large amount of sulfates. This paper mainly focuses on the practical performance of the IC reactor treating molasses wastewater. The removal of COD and sulfate and the production of biogas were studied in the experiment. The result shows that IC reactor presents a good performance of treating medium/high COD concentration wastewater(5000 to 10 000 mg/L). When the COD concentration goes up to 20 000 mg/L, or even higher to 30 000 mg/L, the IC reactor could still keep the COD removal efficiency above 90% when operated for one or two HRT. The maximum volume loading adopted in this trail is increased to around 40 kg COD/m3·d. The concentration of sulfate in the adopted molasses alcohol slops, around 61.9 COD/SO2-4, there is no obvious influence on the performance of the reactor caused by sulfate.
Keywords:IC reactor  molasses wastewater  sulfate  biogas
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《环境工程学报》浏览原始摘要信息
点击此处可从《环境工程学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏