气袋直接进样法测定丙烯腈 |
| |
引用本文: | 李冰清. 气袋直接进样法测定丙烯腈[J]. 环境保护科学, 2012, 38(4): 70-72 |
| |
作者姓名: | 李冰清 |
| |
作者单位: | 上海市环境监测中心,上海,200030 |
| |
摘 要: | 采用气袋直接进样法测定环境和污染源空气中的丙烯腈。结果表明:丙烯腈在0.4~99.5 mg/m3浓度范围内具有良好的线性关系,相关系数为0.999 8。在低、中、高3个添加水平回收率为88.9%~100%,相对标准偏差为0.6%~4.7%,均能较好地满足实验室分析要求。
|
关 键 词: | 气袋 直接进样 丙烯腈 气相色谱 |
Determination of Acrylonitrile by Direct Injection into Airbag |
| |
Abstract: | Acrylonitrile in air environment and air pollution sources was determined by direct injection into airbag. The results showed that calibration curve of acrylonitrile in concentration range of 0.4-99.5 mg/m^3 was linear, and the correlation coefficient was 0.999 8. The recoveries at three levels of low, middle and high were in the range of 88.9%-100%, relative standard deviation were in the range of 0.6%-4.7%, which could met the requirements of lab analysis. |
| |
Keywords: | Airbag Direct Injection Acrylonitrile Gas Chromatography |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
|