土工膜渗漏检测系统的开发
引用本文:能昌信,董 路,王 琪,王彦文,薛咏海,王 斌.土工膜渗漏检测系统的开发[J].环境科学研究,2005,18(4):67-70.
作者姓名:能昌信  董 路  王 琪  王彦文  薛咏海  王 斌
作者单位:1.山东工商学院计算机系,山东烟台,264005
基金项目:国家高技术研究发展计划项目(2001AA644010)
摘    要:通过比较国外多种填埋场渗漏检测方法,成功地研制了基于高压直流电法的渗漏检测系统.该系统利用CAN总线技术,解决了由于填埋场检测面积大所带来的采集数据量大、传输距离远的问题;利用低频脉冲供电方式,将正负半周采集的数据相减,大大减小了低频地电噪声的影响;通过建立合理的地电模型,解决了非均匀介质条件下的电势分布问题,进而提高了系统的检测精度.通过实践检验,表明该系统在检测电极间距为4 m时,误差超过0.4 m的概率低于10%. 

关 键 词:土工膜    渗漏检测    地电模型
文章编号:1001-6929(2005)04-0067-04
收稿时间:20D4-08-23
修稿时间:20D4-08-23

Development of New Leakage Detection System in Geomembrane
NAI Chang-xin,DONG Lu,WANG Qi,WANG Yan-wen,XUE Yong-hai and WANG Bin.Development of New Leakage Detection System in Geomembrane[J].Research of Environmental Sciences,2005,18(4):67-70.
Authors:NAI Chang-xin  DONG Lu  WANG Qi  WANG Yan-wen  XUE Yong-hai and WANG Bin
Institution:1.Computer Department, Industrial and Commercial Institute of Shandong, Yantai 264005, China2.Chinese Research Academy of Environmental Sciences, Beijing 100012, China3.School of Mechatronic Engineering, China University Mining & Technology (Beijing Campus), Beijing 100083, China4.Beijing Industry and Business Commercial University, Beijing 100037, China
Abstract:A new leakage detection system based on high voltage DC method was successfully developed through comparison among foreign methods used in landfill leakage detection. The system uses CAN bus technology and successfully shoots the difficulties of massive data collection and long distance transmission caused by spreading detection area. The low-frequency pulse powering mode is applied and the data collected when supply power is positive and negative are subtracted, which greatly reduces the background noise. Through setting up reasonable earth-electricity model, the distribution problem of electrical potential in uneven medium is resolved and system detection accuracy is improved. The field tests show that the probability of detection error over 0.4 m is no more than 10% , when the space between detection electrodes is 4 m.
Keywords:geomembrane  leakage detection  earth-electricity model