摘    要:利用异相膜电渗析装置去除氨法烟气脱硫浆液中的F~-。考察了脱硫浆液p H、F~-初始质量浓度、Cl~-初始质量浓度、膜堆两端电压、浓缩室和淡化室循环流量等操作参数对F~-去除效果的影响。实验结果表明:在酸性条件下,F~-去除率更高;脱硫浆液中F~-初始质量浓度越高,F~-去除率越高;Cl~-初始质量浓度较低时会增加F~-去除率,过高时又会降低F~-去除率。优化的操作条件为:膜堆两端电压25 V,浓缩室和淡化室循环流量300 L/h。一级电渗析进行100 min后,Cl~-去除率接近100%,F~-去除率只有47.3%。二级电渗析进行100 min时,F~-去除率达92.2%。一、二级电渗析F~-累积去除率达96.1%。

关 键 词:氨法烟气脱硫浆液  氟离子  电渗析  
收稿时间:2017-06-15

Removal of fluorine ion from slurry in ammonia flue gas desulfurization by electrodialysis
Dong Kai,Luo Zhengwei,Guo Mulin,Chen Haonan,Lian Zhouyang,Wei wuji.Removal of fluorine ion from slurry in ammonia flue gas desulfurization by electrodialysis[J].Environmental Protection of Chemical Industry,2018,38(2):175-179.
Authors:Dong Kai  Luo Zhengwei  Guo Mulin  Chen Haonan  Lian Zhouyang  Wei wuji
Institution:1. College of Environmental Science and Engineering,Nanjing Tech University,Nanjing Jiangsu 211816,China;2. College of Safety Science and Engineering,Nanjing Tech University,Nanjing Jiangsu 210009,China;3. College of Chemistry and Chemical Engineering,Nanjing Tech University,Nanjing Jiangsu 210009,China;4. College of Urban Construction,Nanjing Tech University,Nanjing Jiangsu 210009,China
Abstract:F- was removed from the slurry in ammonia flue gas desulfurization using a heterogeneous membrane electrodialysis device. The operating parameters affecting F- removal were studied,such as:slurry pH,initial mass concentration of F- and Cl-,applied voltage,circulation flow of concentrating chamber and desalination chamber,and so on. The experimental results showed that:Acidic condition was conducive to F- removal;The F- removal rate was increased with the increasing of initial F- mass concentration and lower mass concentration of Cl-,but decreased when the initial Cl- mass concentration was too high. The optimum operation conditions were as follows:applied voltage 25 V,circulation flow 300 L/h. The removal rate of Cl- and F- was 100% and 47.3% after the first-stage electrodialysis for 100 min,and after the second-stage electrodialysis for 100 min,the removal rate of F- reached 92.2%. The total F- removal rate was 96.1% by the two-stages electrodialysis.
Keywords:ammonia flue gas desulfurization slurry  fluorine ion  electrodialysis  
本文献已被 CNKI 等数据库收录!
点击此处可从《化工环保》浏览原始摘要信息
点击此处可从《化工环保》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号