Performance study on evacuated tubular collector coupled solar still in West Texas climate
Authors:Roy J Issa  Byungik Chang
Institution:1. School of Engineering and Computer Science, West Texas A&2. M University, Canyon, Texas, USA;3. Department of Civil and Environmental Engineering, University of New Haven, West Haven, Connecticut, USA
Abstract:Experimental study was performed on a single basin active solar distillation system augmented with a solar collector using evacuated solar tubes. Field tests were conducted over several days under the climatic conditions of West Texas to evaluate the effect evacuated solar tubes have on the daily distillate yield rate. To investigate the feasibility of the solar tubes, active and passive solar stills with and without exterior insulation were examined. The maximum daily production rate for the active distillation system using evacuated solar tubes and the passive distillation system was 3.6 and 1.4 kg/m2day, respectively. The results showed the augmentation of the still with evacuated solar tubes increased its production capacity by a factor of 2.63. It also increased the maximum temperature of the water in the still basin by at least 20 °C. Economic analysis shows that it is feasible to use evacuated tubular collector coupled solar still as an alternative means for reclaiming water in farmlands with a payback period of approximately 6 years.
Keywords:Active  passive  solar distillation  vacuum tubes