Abstract: | ABSTRACT: The purpose of this work is to study the installation of artificial aerators for water quality control of a stream which receives thermal and organic waste discharges. The location and numer of diffuser type aerators to be installed along the stream are determined so as to maintain the stream DO content above a certain minimum requirement (4 mg/l or 5 mg/l) for normal aquatic life. Effects of the stream velocity, upstream BOD concentration and rates of thermal and organic waste discharges to the stream are examined. |