摘    要:本文采用零电流示波电位滴定法,测定工业废水中的氰化物,最低检出限可达0.22mg/1,该法与比色法相比,有简便、快速,灵敏等优点。

关 键 词:氰化物  示波滴定  工业废水

DETERMINATION OF CYANIDE BY ZERO CURRENT OSCILLOBIPOTENTIOMETRIC TITRATION
Yin Changqing Jiang Huineng Zhu Jingping Zhang Ling.DETERMINATION OF CYANIDE BY ZERO CURRENT OSCILLOBIPOTENTIOMETRIC TITRATION[J].Environmental Chemistry,1992,11(4):77-80.
Authors:Yin Changqing Jiang Huineng Zhu Jingping Zhang Ling
Abstract:A zero current oscillobipotentiometric titration method was reported for using in environmental monitoring. A couple of Pt and siliver electrodes was used for the end-point indication of titration of CN- by AgNO3.The end-point is found to be easily,the visuable, apparatus and manipulation simple. Results of cyanide determination in industral waste water are satisfactory.
Keywords:cyanide  oscillo-titration  