首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Dynamic response and effect of apertures on explosion parameters of flameproof apparatus
Institution:1. Wroclaw University of Science and Technology, Faculty of Environmental Engineering, Wybrzeże Wyspiańskiego 27, Wrocław 50-370, Poland;2. Wroclaw Centre for Networking and Supercomputing, Wybrzeże Wyspiańskiego 27, Wrocław 50-370, Poland
Abstract:Explosion parameters for closed flameproof apparatus are changed when apertures like gap (e.g. push button) and porous structures (breathing element) are introduced on the cover or wall of the flameproof enclosures. Similarly, an interconnecting tube between two enclosures, results in significant change in explosion parameters. It is observed that the maximum explosion pressure, maximum rate of pressure rise and severity index are higher for enclosures with apertures on cover or body than that of enclosures without apertures. In case of two interconnected identical enclosures, the explosion parameters are increased in the secondary enclosure and higher than that of primary enclosure and also of isolated enclosure.
Keywords:Apertures  Breathing element  Explosion pressure  Flameproof  Severity index  Pressure piling
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号