分光光度法测定叶绿素a的比较
引用本文:童桂凤,陈志芳,范莹.分光光度法测定叶绿素a的比较[J].环境监测管理与技术,2012,24(1):53-55.
作者姓名:童桂凤  陈志芳  范莹
作者单位:扬州市环境监测中心站,江苏扬州225007
摘    要:比较了《水和废水监测分析方法》(第四版)和ISO 10260:1992(E)中测定叶绿素a的典型方法,结果表明两种方法的测定结果之间既存在显著性差异,又有一定的相关性,从提取方法、提取溶剂和计算公式等方面讨论了原因,指出ISO方法提取效率更高,操作更简便。

关 键 词:叶绿素a  分光光度法  水质

Determination Comparison for Chlorophyll-a Concentration by Spectrophotometry
TONG Gui-feng,CHEN Zhi-fang,FAN Ying.Determination Comparison for Chlorophyll-a Concentration by Spectrophotometry[J].The Administration and Technique of Environmental Monitoring,2012,24(1):53-55.
Authors:TONG Gui-feng  CHEN Zhi-fang  FAN Ying
Institution:( Yangzhou Environmental Monitoring Center, Yangzhou, Jiangsu 225007, China)
Abstract:The typical methods for chlorophyll test were compared between water and wastewater monitoring method (the fourth edition) and ISO 10260:1992(E). The experiments showed that the test results both had a certain correlation and significant differences. ISO standard had high extraction efficiency and easy operation in the ways of extraction method, extraction solvent and calculation formula.
Keywords:Chlorophyll-a  Spectrophotometry  Water quality