次氯酸钠衍生-气相色谱法测定水中苦味酸
引用本文:陆梅,丁长春.次氯酸钠衍生-气相色谱法测定水中苦味酸[J].环境监测管理与技术,2012,24(1):50-52.
作者姓名:陆梅  丁长春
作者单位:淮安市环境监测中心站,江苏淮安223001
摘    要:采用次氯酸钠衍生、毛细管柱气相色谱电子捕获检测器测定水中苦味酸,选择正己烷为萃取剂,萃取时间5 min,衍生反应时间40 min。方法在5.00μg/L~100μg/L范围内线性良好,检出限为0.2μg/L,空白加标水样平行测定的RSD为2.2%,加标回收率为89.6%~95.0%。

关 键 词:苦味酸  衍生反应  气相色谱法  水质

Determination for Picric Acid in Water by GC Deriving with Sodium Hypochlorite
LU Mei,DING Chang-chun.Determination for Picric Acid in Water by GC Deriving with Sodium Hypochlorite[J].The Administration and Technique of Environmental Monitoring,2012,24(1):50-52.
Authors:LU Mei  DING Chang-chun
Institution:( Huaian Environmental Monitor Center, Huaian, Jiangsu 223001, China)
Abstract:A method was established for determining Picric Acid in water by GC-ECD.Picric acid in the water was derivatized with sodium hypochlorite in 40 min,and then extracted with n-Hexane in 5 min.Good linearity was obtained in range from 5.00 μg/L to 100 μg/L,detection limits 0.2 μg/L,relative standard derivation of blank duplicates 2.2%,spiked recoveries between 89.6% and 95.0%.
Keywords:Picric acid  Deriving  Gas chromatography  Water quality