首页 | 本学科首页   官方微博 | 高级检索  
     检索      

南京市地铁车站氡浓度水平的初步调查
引用本文:朱晓翔,周程,徐萍.南京市地铁车站氡浓度水平的初步调查[J].环境监测管理与技术,2012,24(1):29-31.
作者姓名:朱晓翔  周程  徐萍
作者单位:[1]江苏省辐射环境监测管理站,江苏南京210019 [2]江苏省辐射环境保护咨询中心,江苏南京210019
摘    要:采用静电收集氡子体法对南京市地铁车站环境中氡浓度进行了调查,初步掌握了南京市地铁站重点区域的氡浓度放射性水平,按照联合国原子辐射效应科学委员会推荐的评价方法估算氡浓度对地铁内工作人员人均年有效照射剂量。对地铁站新建和扩建项目的机械通风设计,为工作人员和公众的内照射剂量水平估算等提供依据。

关 键 词:地铁  氡浓度  静电收集氡子体法  南京市

Preliminary Investigation of Radon Radiological Level in Air of Nanjing Metro Station
ZHU Xiao-xiang,ZHOU Cheng,XU Ping.Preliminary Investigation of Radon Radiological Level in Air of Nanjing Metro Station[J].The Administration and Technique of Environmental Monitoring,2012,24(1):29-31.
Authors:ZHU Xiao-xiang  ZHOU Cheng  XU Ping
Institution:1.Jiangsu Radiation Environment Monitoring and Management Center,Nanjing,Jiangsu 210019,China; 2.Jiangsu Radiation Environment Protection Consultation Center,Nanjing,Jiangsu 210019,China)ZHU Xiao-xiang1,ZHOU Cheng1,XU Ping2 (1.Jiangsu Radiation Environment Monitoring and Management Center,Nanjing,Jiangsu 210019,China; 2.Jiangsu Radiation Environment Protection Consultation Center,Nanjing,Jiangsu 210019,China)
Abstract:The radon level in air of Nanjing metro station has been invested preliminarily by using collect random daughter by static electricity.The radioactivity of radon level of major area in the station are obtained on basis of which,the annual average effective exposure dose of metro workers is given according to the evaluation approach recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation(UNSCEAR).The result can give the suggestive instructions on the engineering design of metro mechanical ventilation as well as the dose evaluation of the public and the metro workers by the radon radiological exposure.
Keywords:Metro  Radon radiological level  Collect radon daughter by static electricity  Nanjing
本文献已被 CNKI 维普 等数据库收录!
点击此处可从《环境监测管理与技术》浏览原始摘要信息
点击此处可从《环境监测管理与技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号