浊点萃取-分光光度法测定水中痕量六价铬
引用本文:金洪洙,张晓霞,刘东方,黄学铭.浊点萃取-分光光度法测定水中痕量六价铬[J].环境监测管理与技术,2009,21(4):51-53.
作者姓名:金洪洙  张晓霞  刘东方  黄学铭
作者单位:长春理工大学化学与环境工程学院,吉林,长春,130022
摘    要:利用非离子表面活性剂Triton X-114的浊点现象萃取,以二苯碳酰二肼为显色剂,采用分光光度法测定水中痕量六价铬,优化了试验条件,考察了共存离子的干扰。方法在0mg/L-12.0mg/L范围内线性良好,检出限为0.0015mg/L,标准溶液测定的RSD为2.7%,水样加标回收率为98.1%-102%。

关 键 词:六价铬  浊点萃取  分光光度法  水质

Determination of Trace Cr(Ⅵ) in Water by Spectrophotometry with Cloud Point Extraction
JIN Hong-zhu,ZHANG Xiao-xia,LIU Dong-fang,HUANG Xue-ming.Determination of Trace Cr(Ⅵ) in Water by Spectrophotometry with Cloud Point Extraction[J].The Administration and Technique of Environmental Monitoring,2009,21(4):51-53.
Authors:JIN Hong-zhu  ZHANG Xiao-xia  LIU Dong-fang  HUANG Xue-ming
Institution:College of Chemistry and Environmental Engineering;Changchun University of Science and Technology;Changchun;Jilin 130022;China
Abstract:A method was established for determination trace Cr(Ⅵ) in water by spectrophotometry with di- phenylcarbohydrazide as color reveal agent and cloud point extraction of surface active agent Triton X-114. The experimental conditions were optimized and effect of interfering ion was observed to produce the following results : good linearity in the range from 0 mg/L to 12.0 mg/L, the detection limits 0. 001 5 mg/L, the RSDs of the standard solution 2.7% , the recoveries of water samples from 98.1% to 102%.
Keywords:Cr(Ⅵ)  Cloud point  Spectrophotometry  Water quality