超高压液相色谱/质谱联用法测定地表水中特定污染物
引用本文:刘浩,邹塞.超高压液相色谱/质谱联用法测定地表水中特定污染物[J].环境监测管理与技术,2014,26(2):39-41.
作者姓名:刘浩  邹塞
作者单位:徐州市环境监测中心站;徐州市环境监测中心站
摘    要:采用超高压液相色谱/质谱联用法测定地表水特定项目中包括微囊藻毒素-LR在内的13种污染物,对测定条件进行优化,使得各目标化合物均能在3min内检测完毕.试验表明,方法在各测定范围内线性良好,相关系数均〉0.99,各目标化合物的方法检出限为0.12μg/L~8.40μg/L,地表水样的加标回收率在62.0% ~104%之间,6次平行测定的RSD〈6%.用该方法测实际水样,阿特拉津和马拉硫磷被检出,质量浓度分别为0.6μg/L和0.7μg/L.

关 键 词:特定污染物  超高压液相色谱  质谱联用法  地表水

The Determination of Certain Pollutants in Surface Water using Ultra High Pressure Liquid Chromatography Tandem Mass Spectrometry
LIU Hao,ZOU Sai.The Determination of Certain Pollutants in Surface Water using Ultra High Pressure Liquid Chromatography Tandem Mass Spectrometry[J].The Administration and Technique of Environmental Monitoring,2014,26(2):39-41.
Authors:LIU Hao  ZOU Sai
Institution:( Xuzhou Environmental Monitoring Centre, Xuzhou, Jiangsu 221006, China )
Abstract:13 pollutants in surface water including Microcystin-LR were determined using ultra high pressure liquid chromatography tandem mass spectrometry method (UPLC-MS/MS). The determination condition was optimized so that all the target compounds could be detected within 3 minutes. The results indicated that: all of the calibration curves showed good linear relationship with a correlation coefficient above 0.99. The determination limits of the targets were from 0.12 μg/L to 8.40 μg/L and the recovery rates of practical surface water samples were between 62.0% and 104%. 6 parallel samples were determined,and the relative standard deviations (RS- Ds) were between 1.8% and 5.7%. When determining the practical water samples using this method, only atrazine and malathion were detected,with a mass concentration of 0.6 μg/L and 0.7 μg/L, respectively.
Keywords:Specific pollutants  Ultra high pressure liquid chromatography tandem mass spectrometry method  Surface water