首页 | 本学科首页   官方微博 | 高级检索  
     检索      

高压密封消解-流动注射同时测定海水中总氮和总磷
引用本文:陈克红,张晴,刘展新,王敏.高压密封消解-流动注射同时测定海水中总氮和总磷[J].环境监控与预警,2020,12(2):41-44.
作者姓名:陈克红  张晴  刘展新  王敏
作者单位:连云港市海洋环境监测预报中心,江苏 连云港 222000,连云港市海洋环境监测预报中心,江苏 连云港 222000,连云港市海洋环境监测预报中心,江苏 连云港 222000,连云港市海洋环境监测预报中心,江苏 连云港 222000
摘    要:建立了高压密封消解-流动注射同时测定海水中总氮和总磷的方法,方法采用特制聚四氟乙烯密封消解罐,经高压消解锅消解后,用流动注射分析仪同时测定海水中的总氮和总磷。结果显示,总氮和总磷在0~3.20 mg/L范围内线性良好,总氮相关系数(r)=0.9997,检出限为0.012 mg/L,相对标准偏差为0.65%~2.59%,加标回收率为97.8%~102%;总磷相关系数(r)=0.9999,检出限为0.006 mg/L,相对标准偏差为0.50%~6.67%,加标回收率为98.8%~101%。该方法可同时测定海水中总氮和总磷,方法准确度和精密度良好,满足分析要求,适用于大批量海水样品中总氮和总磷的快速准确定量。

关 键 词:高压密封消解  流动注射  总氮  总磷  海水
收稿时间:2019/10/10 0:00:00
修稿时间:2019/11/15 0:00:00

Simultaneous Determination of Total Nitrogen and Total Phosphorus in Seawater by High Pressure Sealed Digestion-Flow Injection
CHEN Ke-hong,ZHANG Qing,LIU Zhan-xin,WANG Min.Simultaneous Determination of Total Nitrogen and Total Phosphorus in Seawater by High Pressure Sealed Digestion-Flow Injection[J].Environmental Monitoring and Forewarning,2020,12(2):41-44.
Authors:CHEN Ke-hong  ZHANG Qing  LIU Zhan-xin  WANG Min
Institution:(Lianyungang Marine Environmental Monitoring and Forecasting Center,Lianyungang,Jiangsu 222000,China)
Abstract:A method was established to simultaneously determine total nitrogen and total phosphorus in seawater by high pressure sealed digestion-flow injection.Samples were placed in a special polytetrafluoroethylene sealed digestion tank. After digestion in a high pressure digestion pot,the total nitrogen and total phosphorus in seawater were simultaneously determined by flow injection analyzer. The results showed that the linear equation of total nitrogen and total phosphorus was good in the range of 0~3.20 mg/L.Thecorrelation coefficient of total nitrogen was 0.999 7,and the detection limit was 0.012 mg/L,and RSD value ranged from 0.65% to 2.59%,recovery rate was in the range of 97.5%~103%.The correlation coefficient of total phosphorus was 0.9999,detection limit was 0.006 mg/L,and RSD value ranged from 0.50% to 6.67%,recovery rate was in the range of 98.8% to 101%.The accuracy and precision of simultaneous determination of total nitrogen and total phosphorus in seawater have been improved,it is suitable for rapid and accurate determination of total nitrogen and total phosphorus in a large number of sea water samples.
Keywords:High pressure sealing digestion  Flow injection  Total nitrogen  Total phosphorus  Seawater
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《环境监控与预警》浏览原始摘要信息
点击此处可从《环境监控与预警》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号