首页 | 本学科首页   官方微博 | 高级检索  
     检索      

燃煤锅炉测试过程中运行负荷测定方法探讨
引用本文:毕勇.燃煤锅炉测试过程中运行负荷测定方法探讨[J].环境监控与预警,2014,6(3):24-25.
作者姓名:毕勇
作者单位:葫芦岛市环境监测中心站
摘    要:锅炉运行负荷是锅炉监测获得准确数据的重要条件,但实际监测过程中受各种条件制约,许多锅炉房不具备测试的计量条件。通过一些理论经验公式推导出一个简单的计算锅炉负荷的公式,经过验证,该公式计算值与实测值有较好的一致性。

关 键 词:燃煤锅炉  运行负荷  探讨
收稿时间:2013/2/16 0:00:00
修稿时间:3/1/2014 12:00:00 AM

Study about the Problem of the Operating Load Monitoring in Coal fired Boiler Monitoring
BI Yong.Study about the Problem of the Operating Load Monitoring in Coal fired Boiler Monitoring[J].Environmental Monitoring and Forewarning,2014,6(3):24-25.
Authors:BI Yong
Institution:BI Yong ( Huludao Environmental Monitoring Central Station, Huludao, Liaoning 125000, China)
Abstract:Boiler operating load is the important condition for accurate Boiler Monitoring,but many boiler rooms do not have test measurement conditions constrained by various factors.This paper derived a simple formula to calculate the boiler load by some theo-retical empirical formulas.At last,it is verified that the calculated value has good coherence to measured values.
Keywords:Coal-fired boiler  Operating load  Study
本文献已被 维普 等数据库收录!
点击此处可从《环境监控与预警》浏览原始摘要信息
点击此处可从《环境监控与预警》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号