首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Influence of Relative Humidity and Ozone on the Sampling of Volatile Organic Compounds on Carbotrap/Carbosieve Adsorbents
Authors:Fabienne Palluau  Philippe Mirabel  Maurice Millet
Institution:(1) Laboratoire de Physico-Chimie de l'Atmosphère, Centre de Géochimie de la Surface (UMR 7517 CNRS—Université Louis Pasteur), 1, rue Blessig, F-67084 Strasbourg Cedex, France;(2) Laboratoire Interrégional Grand Est, ASPA, 5, rue de Madrid, F-67309 Schiltigheim Cedex, France;(3) Laboratoire de Physico-Chimie de l'Atmosphère, Centre de Géochimie de la Surface (UMR 7517 CNRS—Université Louis Pasteur), 1, rue Blessig, F-67084 Strasbourg Cedex, France
Abstract:By using a dynamic dilution system, the atmospheric measurement of 11 selected toxics VOCs (ethylene, acetylene, propene, 1-butene, 1,3-butadiene, 1-pentene, 1-hexene, benzene, toluene, ethylbenzene, m+p-xylene) from the list WHO of 1996 and TO-14 method of US EPA by preconcentration by thermal desorption (TD), analysis by gas chromatography (GC), identification and quantification with a flame ionisation detector (FID) was developed and validated in term of metrology, especially the techniques of sampling of these VOCs with adsorbents cartridges "Air Toxics" when used with an "UMEG sampler" equipped in the inlet with a nafion membrane. In particular the influence of climatic conditions (temperature and relative humidity) and the influence of chemical factors like ozone, on the representativity of sampling were studied. Experiments made with various humidities showed that the addition of a nafion membrane in the inlet of the sampling system was required. Without this membrane, losses of compounds were observed for RH >50%. With this membrane, storage for 2 weeks in a refrigerator, as for canisters, did not induce a loss of compounds. No significative decrease of concentrations of the studied VOCs after 14 days storage, which are known to react with ozone, were observed with an ozone concentrations of 55 ppb. One explanation is that nafion membrane, placed in the inlet of the sampler, will neutralize ozone before entering the sampling tubes. This observation is in accordance with literature which states that the sampling of VOCs on Carbotrap cartridges without ozone scrubber induce a loss of compounds.
Keywords:Air toxics cartridges  Dynamic dilution system  nafion? membrane  Ozone precursors VOC  Toxics VOCs
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号