Air quality monitoring for multiple pollutants: Optimization of a network around a hypothetical potash plant and two thermal power stations in open countryside
Authors:F J Serón Arbeloa  C Pérez Caseiras  L J Nogué Lahuerta  P M Latorre Andrés
Institution:(1) Electrical Engineering and Computer Science Department, Universidad de Zaragoza, María de Luna, 3, 50015 Zaragoza, Spain;(2) Fluid Mechanics Department, Centro Politécnico Superior de Ingenieros, Universidad de Zaragoza, María de Luna, 3, 50015 Zaragoza, Spain
Abstract:A method is presented for the design of multi-pollutant air quality monitoring networks (AQMN). This technique leads to an optimal network, i.e. a network providing a maximum of information with a minimum of measurement devices. The spatial correlation analysis technique is used to compare the information given by the potential sites that may form the network. The concept of potential of violation is defined to take into account the number of times that the maximum emission values tolerated by law are exceeded. Both objectives are weighted automatically through an adjustable parameter, b, for which an estimation procedure has been developed in this study, depending on the purpose of the network. Several methods are described, allowing simultaneous consideration of different pollutants. As an illustration of these methods, a number of air quality monitoring networks is designed to perform an analysis of the environmental impact due to a hypothetical potash processing plant and two thermal power stations.